PORTABLE
PROGRAMMER FOR ENCODER/TRANSMITTERS
AND REPEATER
CD-1000
The programmer model PP 200 is designed to visualize and update the
system parameters of units CK 022, CK 024 and CD1000R. It is
accomplished as a portable module, A software version of it for IBM
compatible computers is also available.
Operational Features:
-
Dimensions: 190 x 100 x 35 mm
-
Capability of connection with modules CK-022, CK-024 and
CD1000R.
-
Computer
connection for data base update with information about the
programmed parameters for
each one site.
-
Capability of printing programmed parameters on standard
printers using Centronics interface.
-
LCD
display 2 x 16 characters
-
Sensor-operated keypad with 16 keys
-
Automatic identification of units it is connected to.
-
Capability of programming encoder/transmitter units for sites
numerated from 0 to 8191 and
receiver stations the information is meant for, numerated from 0
to 7. Tins encoder/transmitter
unit is provided with readily programmable parameters through a
computer or a portable
programmer unit PP200.
-
Programmable sensitivity rate for the eight input ports: 100 ms,
200 ms, 500 ms, 1 sec, 2 sec, 5 sec,
10 sec. Disguise for Alarm, Trouble and Restore events.
-
Programmable input port to report Open/Close status of the alarm
central station. Sensitivity rate:
200 ms, 1 sec, 2 sec, 5 sec, 10 sec, 20 sec, 1 min, 2 min.
Disguise for Open and Close events.
-
Input
port setting to report information about presence/absence of
220V with disguise for AC Alarm
and AC Restore events. Frequency-50/60Hz.
-
Capability of reporting about exhausted or restored batteries.
Disguise for Low Bat and Bat Restore
events.
-
Capability of programming a TEST signal transmission through a
period of 5 min. 30 min, 1 hr, 2
hrs, 6 hrs, 12 hrs, 24 hrs. Allows for
shifting of the first test up to 24 hrs after its initial
starting.
-
Possible
changes in the wave parameters caused by the transmission of
each event: transmission
from 1 to 255 times in a package of 1 to 255 repetitions.
Setting of a fixed time interval between each
two transmissions from 1 to 255 sec. and spare time of 1 to 255
sec. This prevents any loss of
information, which might result from overlapping of
transmissions from several subscriber sites at
the same time.
-
Time
setting for transmitter preparation: 0,10 ms, 20 ms, 50 ms, 100
ms, 200 ms, 500 ms, 1 sec.
-
Selection of a radio format for transmission of information via
a radio channel.
-
Selection of a frequency and modes of frequency changes with
regard to the types of events.
-
Power
supply from 8 to 24VDC, power consumption 50mA.
|